How to select wire and cable for PHOTOVOLTAIC power station system - teaching materials TIME:2019-07-07
This document is the 2019 revised version of Shanghai Guangheng Cable, which mainly involves how to select the wire and cable of photovoltaic power station system? It provides important reference for pv cable pV1-F1 *4 and H1Z2Z2-K1*4, how to select signal cable, control cable and junction cable, and laying specifications according to requirements. It is for pv power station construction design and installation circuit system personnel to learn and expand the materials in the early stage, the content is for reference only. Actual power station cable selection needs to be based on the actual situation and the specific comprehensive design planning of professional power station designers and units.
Read More>> -
光伏电缆线两层(绝缘和护套)不分离有影响质量吗?(en) TIME:2023-04-12
带着这个问题,听一听上海光亨电缆有限公司技术人员怎么回答的:“TUV光伏电缆一般要求需要二层绝缘层,也就是常说的内绝缘层和外护套,而两层绝缘可分离和两层绝缘层不可分离均是正常的工艺要求,不影响产品质量。” 小编:“为什么要做两层可分离和不可分离的工艺呢?哪种更节省成本?哪种使用效果更好呢?”技术:“我们可以做分离和不分离的两种,并无任何技术难题,关键点就是做外护套的时候有没有加滑石粉或者(en)
Read More>> -
线缆国家职业标准和各工种的鉴定规范(en) TIME:2023-02-13
电线电缆工厂需要哪些工种?根据《中华人民共和国劳动法》的有关规定,劳动和社会保障部组织有关专家,制定了《电线电缆制造工国家职业标准》(简称《标准》),用以指导全国线缆行业开展职业技能鉴定。《标准》依据有关规定,将本职业分为五个等级,在充分考虑经济发展、科技进步和产业结构变化对本职业影响的基础上,对本职业的活动范围、工作内(en)
Read More>> -
TUV EN50618:2014 PV cable H1Z2Z2-K1*2.5/4/6/10mm2 mm2 carrying capacity and detailed technical parameters table TIME:2022-04-24
TUV EN5068:2014 SERIES DC1500V PHOTOVOLTAIC cable H1Z2Z2-K commonly used at home and abroad, the main specifications of 1.5~10mm² square mm, the corresponding maximum load, outer diameter, conductor structure and other related technical parameters of the solar cable, a table covers all:
Read More>> -
What is the resistance of 4 square pv cable? TIME:2022-03-11
Photovoltaic cable in addition to insulation and sheath layer or double layer co-extrusion (a layer of thickened insulation) must be irradiated crosslinking and other key processes, there are some electrical properties must be achieved, such as photovoltaic cable conductor resistance in the air at 20℃ is what? Is there any evidence? Shanghai Guangheng Cable Co., Ltd. according to the above questions to reply and answer: The conductor resistance of PV1-F1*4 and H1Z2Z2-K1*4 in air at 20℃ is required to be ≤5.09 ohm/km
Read More>> -
Dc photovoltaic cable procurement and sales personnel must pay attention to the misunderstanding, confused may lead to photovoltaic power station can not be accepted! TIME:2022-02-25
As the market continued demand for photovoltaic power station, and related supporting product technology optimization and upgrade of photovoltaic dc cable and certification are updated several versions, we in the two common types of voltage problem for pv cable easily mistaken by according to the interpretation of
Read More>> -
How to calculate the appropriate specification section size of photovoltaic cable through the formula TIME:2021-11-16
A Photovoltaic installation company in Guangdong shall follow a set of 20KW distributed solar photovoltaic power station with 9 pieces in 1 series and then 3 groups in parallel. The power of each photovoltaic panel is 450W, the open-circuit voltage is 41V and the working voltage is 34.7V. After we know the above parameters, we can deduce the voltage and current parameters of the output circuit. If the parameters are within the technical parameters of the photovoltaic wire, it can be used in theory
Read More>> -
Why does the solar DC photovoltaic cable in the photovoltaic power station use tinned copper wire? TIME:2021-08-10
Why does the solar DC photovoltaic cable in the photovoltaic power station use tinned copper wire? Solar dc photovoltaic cables are mainly UL, PSE, TUV these categories, the current consumption is large, widely used in China is TUV standard products, here mainly and readers talk about TUV photovoltaic cable conductor material why choose tinned copper wire (conductor according to IEC 60228,5 classes stranded tinned copper wire), As opposed to some other conductor material? First of all, what is the main material of domestic wire and cable conductor? What are the pros and cons? 1, general aluminum conductor advantages: first, cheap (EN)
Read More>> -
How to choose outdoor anti ultraviolet and sun resistant wires and cables? TIME:2021-08-07
Recently, a customer came to inquire whether they can customize a wire and cable that can be used outdoors and prevent ultraviolet rays and sun aging? Xiaobian made a further understanding of this pro
Read More>> -
62930 what is IEC 131 cable TIME:2021-07-23
62930 IEC 131 DC1500V DC photovoltaic cable TUV certification 62930 IEC 131 solar photovoltaic cable is a relatively recent certified product in the market. It is a DC photovoltaic cable standard product formulated by the International Electrotechnical Commission. It is mainly used in the power transmission of photovoltaic panel DC circuit of photovoltaic power station and the production and manufacturing of various photovoltaic connectors.
Read More>>