CAUTION -DO NOT DISCONNECT UNDER LOAD DC Solar (PV) Cable PV1-F 2x4.0mm2 AC 0.6/1 KV - DC 0.9/1.8 KV

image.png

Solar Cable

Application
Double insulation, electron-beam cross-linked cables for photovoltaic power station.

Especially for the connection between Solar power generation device connector and connection of inverter,Under the condition of different climate outdoor installation,and can adapt to the dry and wet indoor working environment


Construction
Conductor: Tinned copper, according to the VDE 0295/ IEC 60228,Class5
Insulation: Polyolefin copolymer electron-beam cross-linked
Outer Sheath: Polyolefin copolymer electron-beam cross-linked
Sheath color: Black/Red/Blue or as per customer's requeit

Technical Specification
Nominal Votage: U0/U=600/1000VAC,1000/1800VDC
Test Voltage: 6500V,50Hz,5min
Temperature Rating:
-45ºC ~ +125ºC
-40°F ~ +257°F
Ambient temperature
-40ºC ~ +90ºC
-40°F ~+194°F
Max. Short circuit temperature:280ºC,+536°F
Bending Radius: Fixed installation>4X,  Occasionally moved>5X

Material Properties/ Standards
Fire-resistance performance: IEC 60332-1
Smoke emission: IEC 61034; EN 50268-2
Low fire load: DIN 51900
Approvals: TUV 2PfG 1169/08.2007 PV1-F
Application standards: UNE 211 23; UNE 20.460-5-52,UTE C 32-502